Control and automation malfunctions reported in detail to TD
Failure of a critical system, PLC, process computer or production line can have major consequences for safety, the environment and production. Industrial processes are often chain-linked: if one link fails, processes before and after it will also come to a standstill (after a certain amount of time and depending on buffers). This leads to loss of production, waiting employees, logistical delays (loading/unloading), late deliveries and possible additional machine damage. Utilities such as steam may also fail, material shortages may shut down the line, and environmental problems may arise, such as the discharge of wastewater outside the norm, resulting in fines.
Therefore, report malfunctions and breakdowns immediately to the on-duty repair engineer(s), even outside working hours. Rapid intervention limits downtime, prevents escalation and ensures continuity, safety and compliance with environmental requirements.
Alert functions we offer
- Reporting technical malfunctions (such as mechanical malfunctions, control and automation malfunctions, instrumentation and sensor malfunctions, hydrolysis and pneumatic malfunctions, and electrical malfunctions) to the technical service on duty via smartphone or pager.
- Remote activation and deactivation of alarms and/or departments.
- Local alarm on site possible via buzzer and flashing light.
- Detection and reporting of power failures in critical systems or production processes (with built-in emergency power supply).
- Internal line monitoring on telephone connection in case of line failure.
- 24/7 monitoring of unmanned, critical locations.
- Insight into all current statuses anytime, anywhere.
NEW: integration of Siemens PLC S7-1200 and S7-1500 series now in pilot phase.
Want to know more? Read on further down this page.
In this sector you will find our
Testimonials: the floor is up to the customer
Insight into your production process, PLC system or storage tank provides peace of mind and certainty
NEW: integration of Siemens PLC S7-1200 and S7-1500 series (pilot phase)
Siemens PLCs are widely used to control a variety of industrial processes. In the event of a malfunction in the process or in the process control, it is important that the technical department is notified in good time. By connecting Siemens PLCs via the network to an Octalarm Touch-Pro with Octalarm Link licence, malfunction information about the nature and cause can be included directly from the PLC in the alarm message. This makes it easier to interpret the malfunction and determine its urgency more easily and accurately.
Read more about the Octalarm Touch Pro Read more about Octalarm Link
Do you have a pilot project for our new connection?
Test the integration of Siemens PLC S7-1200 and S7-1500 series with Touch Pro (with Link licence)
Technology is only valuable when it is safe, stable and user-friendly. That is why we like to test our innovations in practice—preferably together with (future) end customers and installers. And so we are looking for pilot projects for our new link between Siemens PLCs and Touch Pro (with Octalarm Link licence).
The PLC software module (JSON protocol) for Siemens PLCs was developed in TIA Portal V18, but can be converted to V17 and V16 if desired.
Requirements for participation
- Both an end customer and an installer are involved in the project.
- A PLC programmer is available. (If desired, we can put you in touch with an external party who is familiar with this link.)
- A test environment is preferred. If you are testing in a production environment, we strongly recommend running a redundant PLC.
Points to note during testing
- Programming the connection between the Siemens PLC and the alarm device (manual available).
- Installation and configuration of the alarm (manual available).
- Testing of the alarm handling: Siemens PLC → alarm dialler.
- Biweekly feedback session on:
- progress of the pilot;
- findings and areas for improvement.
Period
- Minimum test duration: 1 month.
- Desired test duration: 2 months.
Yes, I would like to test it!
Do you have a project that is suitable for this pilot? Please contact our sales department. We are available Monday to Friday from 8:30 a.m. to 5:00 p.m. (We have lunch together from 12:30 p.m. to 1:00 p.m. We are closed on national holidays.)
Always safe and compliant: reliable alarm monitoring for fuel tank installations
- Complies with the legal requirement for unmanned petrol stations to have an alarm system.
- Alerts you if the temperature in the pumps gets too high.
- Continues to work during power failures thanks to a built-in emergency battery (standalone).
- Receive notifications and view the live alarm status via the Adésys Alarm App.
Would you like to know what we can do for you?
Please contact us
Applications that run to everyone's satisfaction
- Alewijnse connects Octalarm-Touch Pro to Scada Cimplicity. Read the showcase about how this connection came together.
- Fully integrated alarm notification in the Lely network for dairy farmers. All Lely Industries machines, such as the A4 milking robot, the Discovery manure scraper and the Juno feed pusher, are monitored in this way.
- Monitoring of various production processes in the food and pharmaceutical industries.
Would you like to know what we can do for you?
Don't miss relevant information about alarms and telecom network changes
Subscribe to our newsletter and receive regular updates about specific alarm products or developments for livestock farming. We take your privacy seriously and therefore point out our privacy statement. After registration you can unsubscribe at any time by clicking 'unsubscribe' in the footer of each newsletter or better yet, adjust your preferences so that you only receive the information that is relevant to you.